The difference between a $300 pipe repair and a $3,000 drywall-and-remediation job is often just whether the leak was found before or after excessive wall opening. Our detection service in South Yarmouth uses the same methods utilities and insurance adjusters rely on โ to pinpoint the failure before anything is cut.

No single detection method works for every leak scenario. Our techs are trained on four distinct approaches and select the right tool โ or combination โ based on pipe type, building construction, and leak characteristics.
Pressurized supply line leaks create a low-frequency sound as water escapes the pipe and contacts surrounding soil or structure. Our amplified listening devices filter background noise so we can triangulate the loudest point โ often to within 6โ12 inches of the actual break, through concrete slabs or behind drywall.
Active water leaks create temperature differentials on the surfaces they contact. An infrared camera shows these as color-coded heat maps, revealing the wet zone inside a wall or under a floor without any cutting. A cold water leak behind drywall appears as a spreading cool zone; a hot water leak shows the inverse.
We isolate the supply system, pressurize to operating pressure, and monitor over a timed hold period. Any pressure drop confirms active water loss from the supply side. By isolating zones โ hot side vs. cold side, section by section โ we narrow down which branch is leaking before deploying detection equipment.
Tracer gas is the method of last resort for the most challenging cases. It adds setup time but finds leaks that acoustic and thermal methods alone can't conclusively locate.
Hidden leaks occur in different locations throughout a property โ each requiring a slightly different detection approach. Here's how we handle the most common scenarios in South Yarmouth, MA.
Supply lines running under or through the concrete slab fail from corrosion, shifting, or manufacturing defects โ and the leak is invisible from the surface but audible to acoustic equipment. We walk the floor on a grid pattern, map the loudest detection points, and triangulate to a specific floor location, typically within a square foot. Confirmed slab leak location is documented with marked coordinates for the repair crew.

We document the thermal anomaly, mark the approximate pipe location, and recommend a minimal access cut rather than a wide wall opening โ typically saving hundreds in drywall repair costs.
We also perform leak correlation surveys for longer line runs, using two listening points to triangulate the failure location mathematically.
Irrigation system leaks in main supply and lateral runs are found by isolating zones with the irrigation controller and pressure-testing each zone individually. Zone-by-zone testing narrows the failure to the smallest possible section.

We format detection reports specifically for insurance submission and provide documentation on our detection equipment and methodology to claims adjusters on request.
Commercial buildings have complex pipe networks where a supply or drain leak can go undetected through multiple floors before surfacing. We approach commercial detection systematically โ zone-by-zone pressure isolation, thermal scan of suspect surfaces, and acoustic confirmation.
Finding a hidden leak isn't a single step โ it's a protocol that combines water loss confirmation, zone isolation, and targeted detection in sequence.
We start at the meter. All fixtures off, we watch the meter for 10 minutes. Movement confirms active water loss from the supply side. We also check for visible evidence โ stains, soft floors, moisture readings with a moisture meter at suspect wall surfaces.
We isolate the supply system into zones โ hot side, cold side, individual branches โ and pressure-test each to determine which is losing water. This narrows the area of active search before detection equipment is deployed.
We document findings with thermal images and note detection readings at multiple grid points to triangulate the strongest signal.
Insurance-formatted reports are available for claims submission at the same standard โ no additional cost.

High-efficiency home with a slow leak โ about 1.5 gallons per hour. The tech used tracer gas after pressure testing confirmed the loss but acoustic detection couldn't localize it clearly. Gas detection found the escape at a micro-fitting under the slab in the utility corridor. Impressive work for a very difficult leak to find.
Our insurance company required professional leak detection documentation before approving the claim. Masters Plumbing Service's written report with pressure test data and thermal imagery was exactly what the adjuster needed. Claim approved. The detection cost was covered as part of the claim.
Commercial building with elevated water costs for six months. Masters Plumbing Service ran zone-by-zone pressure isolation across four floors, narrowed the loss to the third-floor kitchen supply branch, and located the failure with thermal imaging at a concealed valve body in the ceiling. No damage to the finished ceiling.
Our detection technicians are equipped with acoustic, thermal, and tracer gas tools for the full range of leak scenarios found in South Yarmouth, MA homes and commercial properties.

Call now to schedule โ most detection appointments available within 24โ48 hours.
๐ Call +1-844-833-0201 Now